A1 HYDROGEL



OVERVIEW

SunP Gel A1 is a biodegradable bio-ink developed for 3D bioprinting. It has good biocompatibility and fast degradation making it suitable for most human and animal-derived cells. The cell survival rate after printing is higher than 85%, and the product comes in both gel & powder form



ADVANTAGES

- Good biocompatibility, degradable
- Good molding effect and long structure retention time (more than 30 days)
- Easy to operate, mix with cell suspension to print
- Wide range of applications, suitable for most human and animal cells

Interested? We would love to talk with you!

TECHNICAL SPECIFICATIONS

  • A1 HYDROGEL
  • A1 FREEZE-DRIED POWDER
A1 HYDROGELA1 FREEZE-DRIED POWDER
Gel
Powder
FormColorless or light yellow gelatinousWhite lyophilized powder
PackagingOne 3ml hydrogel in each boxTwo bottles of 500ml lyophilized powder in each box
Stocking Time3 days7-10 days
SolubilityPlace in a 37-40 ° C oven for 20 min, the product is in a fluid form, can be mixed with PBS, saline, complete medium, etc.Add PBS, saline, complete medium and other solvents in proportion, place in a 40 ° C oven or water bath, completely dissolved in 30 minutes
SterilizationSterileNon-sterile
pH Value7.0- 7.57.0-7.5
Shelf life3 months6 months
Storage Method4°C4°C
Buy NowBuy Now

RHEOLOGICAL PROPERTIES

A1 GEL

antoning
Figure 1: Gel point detection method. Gel point test results: 23.0-25.0 °C

A1 POWDER

ANTO
Figure 2: Gel point detection method. Gel point test results: 24.0-26.0 °C

The gel temperature was measured by Anton Paar MCR302 rotational rheometer. Measurement parameters: deformation range 0.1%, test frequency 1 Hz, cone plate diameter 25 mm, cone plate slope 2 °, cone plate The distance between the tip of the cone and the bottom plate is 99 μm. Gel point test results: 24.0-26.0 °C

CELL VIABILITY STUDIES

A1 GEL

a1 hydrogel

A1 POWDER

missing cell viability image

Figure 3: HUVEC-24h live staining

The cell viability of Hela, A549, NIH-3T3 and HUVEC cells was detected by Calcein AM-PI kit for 24 hours. Under confocal observation, the living cells showed green fluorescence and the dead cells showed red fluorescence (Figure 3). 

CELL VIABILITY TEST RESULTS

Cell typeHelaA549NIH-3T3HUVEC
Survival rate≥90%≥85%≥90%≥90%

 

Figure 4: HUVEC-24h live staining

The cell viability of Hela, A549, NIH-3T3 and HUVEC cells was detected by Calcein AM-PI kit for 24 hours. Under the confocal observation, the living cells showed green fluorescence and the dead cells were red. Fluorescence (Figure 4).

CELL VIABILITY TEST RESULTS

Cell typeHelaA549NIH-3T3HUVEC
Survival rate≥90%≥90%≥85%≥90%

PRINTING APPLICATION EXAMPLE

Bio-ink was prepared by mixing NIH-3T3 cell suspension with SunP Gel A1, and the three-dimensional structure was printed. The culture medium was cultured for 7 days, and the cells were proliferated from single cells into cell clusters. The specific morphology is shown in Figure 5.

A1 APP

Figure 5: NIH-3T3 cell mass (7day)